The StrongArm 28 is an industrial barrier arm operator designed and manufactured by HySecurity. Capable of lifting a 28ft barrier arm to 90° in just 5 seconds, this barrier arm is made with security and accessibility in mind. Arm remains vertical when held open. The center yoke mount is capable of supporting a 28ft arm. Aluminum or aluminum-fiberglass arm options available. Keyed T-lock protects all electrical controls and parts in secure uni-body 10 gauge welded and zinc plated steel chassis.
Featured:
- Duty Cycle: 2,000 cycles/day
- Horsepower: 3/4hp
- Drive: Hydraulic
- Open/Close Time: 5s open/6s close
- Arm Length Max*: Up to 28ft*
- Arm Design: Center yoke. Aluminum up to 24 ft, fiberglass up to 16 ft, or aluminum-fiberglass 26+ ft
- Full Open Angle: 90°
- Temperature Rating: -40° to 158° F No heater necessary
- 1 Phase Power: 115/208/230V 60 Hz, 110/220V 50 Hz
- 3 Phase Power: 208/230/460 or 575V † 60 Hz, 220/380V 50 Hz
- Communication: RS-232, RS-485, Ethernet/fiber using optional HyNet Gateway Accessory
- User Controls: Smart Touch Controller with 70+ configurable settings. Smart Touch keypad and display or a PC using S.T.A.R.T. software.
- Relays: Three configurable user relays: one 30VDC, 3A solid state and two 250VAC, 10A electromechanical; Optional Hy8Relay™ for 8 additional relay outputs
- Finish: Zinc plated with yellow powder coating
- Listed to UL: Usage Class I, II, III, IV
- Warranty: 5 year
Optional Accessories:
- Hy5B™ intelligent vehicle detectors
- Hy8Relay™ - extended relay module provides eight additional programmable relay outputs
- HyNet™ Gateway for communicating gate system and accessory status in real time via Ethernet/fiber.
- Arm light kit
- Heater
*Arms 20ft or longer require counterweights.
SKU | S-HTG-1-52 |
---|---|
Max. Arm Length | 28 ft. |
Operator Type | StrongArm |
Input Voltage | 110/115/120 AC (60Hz, 1 Phase), 220/230/240 AC (60Hz, 1 Phase), 208 AC (60Hz, 1 Phase), 208 AC (60Hz, 3 Phase), 460/480 AC (60Hz, 3 Phase) |
Duty Cycle | 2000 Cycles Per Day |
Manufacturer | Nice | HySecurity |
UL 325 Usage Class | Class I, Class II, Class III, Class IV |
Operating Time | 5 s open / 6 s close |