HySecurity HydraWedge SM50 UPS Hydraulic Anti-Ram Vehicle Barrier Wedge

This is a high voltage UPS Battery Backup model HydraWedge (208/230 VAC, 50/60 Hz - AC-2-C8).

HydraWedge SM50 UPS is a hydraulic barrier wedge built for the defense of high-security areas. High cycling of 300 cycles / hr. allows this model to be utilized routinely and reliably. This barrier wedge has an operating time of 3 seconds (3s open / 3s close). In the event of an emergency, this wedge is equipped with EFO (Emergency Fast Operation) allowing for deployment of just 1 second. This Uninterruptible Power Supply (UPS) model includes a DC Power Supply 120 that provides hundreds of cycles after AC power loss

*​Please Note: Product Pricing Not Available Online. Please Call: (800) 878-7829

Part Number: HYDRAWEDGESM50-HV

Details

HySecurity HydraWedge SM50 UPS Hydraulic Anti-Ram Vehicle Barrier Wedge

The HydraWedge SM50 UPS is an Anti-Ram Vehicle Barrier Wedge designed and manufactured by HySecurity. This barrier wedge is built for the defense of high-security locations worldwide. The certified HydraWedge SM50 UPS has attained several of the toughest domestic and international Crash Certifications, proving the operator's reliability and performance. Tough and resilient, the HydraWedge SM50 UPS is made with a powder-coated steel chassis. The HydraWedge SM50 UPS is an optimal solution for the defense of any high-security location. This Uninterruptible Power Supply (UPS) model includes a DC Power Supply 120 that provides hundreds of cycles after AC power loss.


*​Please Note: Product Pricing Not Available Online. Please Call: (800) 878-7829


Features:

  • Crash Certified: Domestic ASTM F2656 M50-P1 and international IWA 14-1 V/7200[N3C]/80/90:0.0 and PAS68 V/7500[N3]/80/90:0.0/20.7 with no penetration ††
  • Duty Cycle: 300 cycles/hr
  • Horsepower: 2 hp
  • Drive: Hydraulic
  • UPS Battery Voltage: 208-230V 60/50Hz
  • Open/Close Time: 3 seconds
  • Emergency Fast Operation: 1 second
  • Manual Operation: Hand Pump (standard)
  • Wedge Design:
    • Plate width: 2,2.5, 3, 3.5, 4 m* (6.5, 8, 10, 11.5, 13 ft)
    • Plate height (raised): 1000 mm (3.3 ft)
    • Excavation width: Plate width + 700 mm (27.5 inch)
    • Excavation length: 3.7 m (12 ft)
    • Excavation depth:** 300 mm (1 ft)
  • Wheel Load: 44,000 lb axle load rating; 22,000 lb wheel load (19,958 Kg. / 9,979 Kg)
  • Uninterruptible Power Supply: Hundreds of cycles after AC power loss with DC Power Supply w/ HyCharger DC™ ***
  • Accumulator Backup Cycles; Either normal or EFO: 4 accumulator cycles in addition to hundreds of UPS cycles. 2.5 gallon accumulator
  • 1 Phase Power: 115V 60/50Hz 23A † or 208-230V 60/50Hz 11.5A; Choose voltage with care as chargers are not field convertible
  • 3 Phase Power: N/A
  • Batteries: Two 110 Ah batteries located in separate DC UPS enclosure
  • Temperature Rating: -40° to 158° F (-40° to 70° C) or -10° to 158° F (-23° to 70° C) HySecurity specified biodegradable fluid
  • Communication: RS-232, RS-485, Ethernet/fiber using optional HyNet™ Gateway accessory
  • User Controls: Smart Touch Controller with 70+ configurable options. Smart Touch keypad and display or a PC using S.T.A.R.T. software.
  • Relays: Three configurable user relays: one 30VDC, 3A solid state and two 250VAC, 10A electromechanical; Optional Hy8Relay™ for 8 additional relay outputs
  • Enclosure:HydraSupply XL: Type 3R, 91w x 122h x 41d cm (36w x 48h x 16d inch), optional NEMA 4X DC Power Supply: Type 3R, 76w x 76h x 30d cm (30w x 30h x12d inch)
  • Finish: Powder coated, 2,000 hr salt spray tested
  • Foundation: 300 mm** (1 ft) concrete depth all widths up to 4.15 m (13.5 ft); less than 218 kg (480 lb) rebar; less than 3.1 m3 (4 cu yds) concrete (per wedge)
  • Electrical Certification: Control panel certified to UL 508A by ETL
  • Warranty: 5 year warranty on electronics and hydraulics. 2 year warranty on mechanical wedge.

Optional Accessories:

* Wedge manufactured in metric scale. Use for precision measurements. All imperial measurements rounded to nearest ½ ft

** 300 mm excavation: 200 mm reinforcing concrete + 100 mm roadway surface of any material

*** The operator’s normal duty cycle and the actual number of combined cycles available from batteries depends upon wedge plate weight, number of batteries, state of charge and health, ambient temperature, accessory power draw and length of power outage

† 115V input requires 30A branch circuit

†† Contact HySecurity to receive a copy of the ASTM F2656-15 M50-P1 Test Certification

Prefer to Call? (888) 378-1127

Questions about part number HYDRAWEDGESM50-HV?

Required Fields *

Name *

Email *

Phone

My Questions *

SKU HYDRAWEDGESM50-HV
Operator Type HydraWedge SM50
Input Voltage 110/115/120 AC (60Hz, 1 Phase), 220/230/240 AC (60Hz, 1 Phase), 208 AC (60Hz, 1 Phase), 230 AC (50Hz, 1 Phase)
Duty Cycle 300 Cycles Per Hour
Manufacturer Nice | HySecurity
UL 325 Usage Class No
Operating Time 3s open / 3s close