HySecurity HydraWedge SM50 UPS Hydraulic Anti-Ram Vehicle Barrier Wedge

The HydraWedge SM50 UPS is a high-security hydraulic wedge with built-in battery backup for power failure scenarios. It cycles 300 times per hour and opens/closes in 3 seconds. The included DC Power Supply 120 supports hundreds of cycles after AC loss, ensuring uninterrupted security.

Like this product? Call SecureOpeners for expert advice, personalized pricing, and help making sure you get exactly what you need for your project. (888) 378-1127

Please also review the linked order form(s) to ensure you are selecting the correct sizes, lengths, quantities, and any necessary components for your project. While you may not need to submit the form, it serves as a helpful guide to avoid missing any required items. Orders placed without the appropriate selections may be delayed or require additional follow-up. Contact us if you have any questions before ordering.

Order Form
Part Number: HYDRAWEDGESM50-HV
 

Details

HySecurity HydraWedge SM50 UPS Hydraulic Anti-Ram Vehicle Barrier Wedge

The HySecurity HydraWedge SM50 UPS is a high-security anti-ram wedge barrier designed to defend critical access points against vehicular threats. Certified to ASTM M50-P1, IWA 14-1, and PAS 68 standards with zero penetration, the HydraWedge SM50 UPS delivers top-tier crash protection for government, military, and high-risk commercial sites. The system operates reliably even during power outages thanks to its integrated DC Power Supply 120 UPS and high-capacity battery backup. Its hydraulic drive, shallow foundation, fast operation, and compact footprint make it an ideal solution for high-volume security lanes where both high performance and redundancy are required.

Features

  • Crash certified to ASTM F2656 M50-P1, IWA 14-1, PAS 68 with zero penetration
  • Continuous duty cycle: up to 300 cycles/hour
  • Uninterruptible power supply provides hundreds of cycles after AC power loss
  • Hydraulic drive system with 2 HP motor and standard hand pump backup
  • Emergency fast open/close in 1 second
  • Multiple plate width configurations for various lane widths
  • Powder-coated steel chassis, salt spray tested to 2,000 hours
  • Shallow 300 mm (1 ft) foundation depth reduces installation cost and site disruption
  • ETL certified control panel to UL 508A
  • 5-year warranty on electronics and hydraulics; 2-year warranty on mechanical wedge

Specifications

  • Crash Certification: ASTM F2656 M50-P1, IWA 14-1, PAS 68
  • Duty Cycle: 300 cycles/hour
  • Drive Type: Hydraulic
  • Horsepower: 2 HP
  • UPS Backup: Hundreds of cycles via HyCharger DC power supply
  • Accumulator Backup: 4 accumulator cycles with 2.5 gallon accumulator
  • Open/Close Time: 3 seconds (normal), 1 second (EFO)
  • Manual Operation: Hand pump (standard)
  • Plate Widths: 2m, 2.5m, 3m, 3.5m, 4m (6.5, 8, 10, 11.5, 13 ft)
  • Plate Height (Raised): 1000 mm (3.3 ft)
  • Excavation Width: Plate width + 700 mm (27.5 in)
  • Excavation Length: 3.7 m (12 ft)
  • Excavation Depth: 300 mm (1 ft)
  • Wheel Load Capacity: 22,000 lb per wheel (44,000 lb axle load)
  • Power Input (1 Phase): 115V 60/50Hz 23A or 208-230V 60/50Hz 11.5A
  • Batteries: Two 110 Ah batteries (in separate DC UPS enclosure)
  • Temperature Range: -40°F to 158°F (with biodegradable fluid option -10°F to 158°F)
  • Communication: RS-232, RS-485, Ethernet/fiber via optional HyNet Gateway
  • User Controls: Smart Touch controller with 70+ configurable settings
  • Relays: 3 configurable user relays (1 solid-state, 2 electromechanical)
  • Enclosure: HydraSupply XL (36w x 48h x 16d inch), optional NEMA 4X DC Power Supply (30w x 30h x 12d inch)
  • Finish: Powder coated, 2,000-hour salt spray tested
  • Foundation: 300 mm (1 ft) depth; less than 480 lb rebar and 4 cu yds concrete per wedge
  • Certification: UL 508A (control panel)
  • Warranty: 5 years (electronics & hydraulics), 2 years (mechanical wedge)

*Wedge manufactured in metric scale. Use metric for precision measurements. All imperial measurements rounded to nearest foot.

**300 mm excavation consists of 200 mm reinforcing concrete + 100 mm roadway surface of any material.

***UPS cycles may vary based on accessory load, battery condition, cycle frequency, and temperature.

****115V input requires 30A branch circuit.

HydraWedge Model Comparison

  HydraWedge SM50 HydraWedge SM50 UPS (Low Voltage) HydraWedge SM50 Twin HydraWedge SM50 Twin UPS (Low Voltage) HydraWedge SM50 UPS (High Voltage) HydraWedge SM50 Twin UPS (High Voltage)
Drive Type Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic
Horsepower 2 hp 2 hp 5 hp 4 hp 2 hp 4 hp
Duty Cycle 300 cycles/hr 300 cycles/hr 400 cycles/hr (divided) 400 cycles/hr (divided) 300 cycles/hr 400 cycles/hr (divided)
Open/Close Time 3 seconds 3 seconds 3 seconds 3 seconds 3 seconds 3 seconds
Emergency Fast Operation (EFO) 1 second 1 second 1 second 1 second 1 second 1 second
UPS Backup Accumulator: 6 cycles UPS: Hundreds of cycles; Accumulator: 4 cycles Accumulator: 6 cycles (divided) UPS: Hundreds of cycles; Accumulator: 4 cycles (divided) UPS: Hundreds of cycles; Accumulator: 4 cycles UPS: Hundreds of cycles; Accumulator: 4 cycles (divided)
Power Requirements 1 Phase: 208/230V 60Hz; 220V 50Hz
3 Phase: 208/230/460V; 220/380/440V 50Hz
115V 60/50Hz 1 Phase: 230V 60Hz; 220V 50Hz
3 Phase: 208/230/460V; 220/380/440V 50Hz
115V 60/50Hz 208-230V 60/50Hz 208-230V 60/50Hz
Crash Certification ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68

HydraWedge Model Comparison

  HydraWedge SM50 HydraWedge SM50 UPS (Low Voltage) HydraWedge SM50 Twin HydraWedge SM50 Twin UPS (Low Voltage) HydraWedge SM50 UPS (High Voltage) HydraWedge SM50 Twin UPS (High Voltage)
Drive Type Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic Hydraulic
Horsepower 2 hp 2 hp 5 hp 4 hp 2 hp 4 hp
Duty Cycle 300 cycles/hr 300 cycles/hr 400 cycles/hr (divided) 400 cycles/hr (divided) 300 cycles/hr 400 cycles/hr (divided)
Open/Close Time 3 seconds 3 seconds 3 seconds 3 seconds 3 seconds 3 seconds
Emergency Fast Operation (EFO) 1 second 1 second 1 second 1 second 1 second 1 second
UPS Backup Accumulator: 6 cycles UPS: Hundreds of cycles; Accumulator: 4 cycles Accumulator: 6 cycles (divided) UPS: Hundreds of cycles; Accumulator: 4 cycles (divided) UPS: Hundreds of cycles; Accumulator: 4 cycles UPS: Hundreds of cycles; Accumulator: 4 cycles (divided)
Power Requirements 1 Phase: 208/230V 60Hz; 220V 50Hz
3 Phase: 208/230/460V; 220/380/440V 50Hz
115V 60/50Hz 1 Phase: 230V 60Hz; 220V 50Hz
3 Phase: 208/230/460V; 220/380/440V 50Hz
115V 60/50Hz 208-230V 60/50Hz 208-230V 60/50Hz
Crash Certification ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68 ASTM F2656 M50-P1; IWA 14-1; PAS68
Prefer to Call? (888) 378-1127

Questions about part number HYDRAWEDGESM50-HV?

Required Fields *

Name *

Email *

Phone

My Questions *

SKU HYDRAWEDGESM50-HV
Operator Type HydraWedge SM50
Input Voltage 110/115/120 AC (60Hz, 1 Phase), 220/230/240 AC (60Hz, 1 Phase), 208 AC (60Hz, 1 Phase), 230 AC (50Hz, 1 Phase)
Duty Cycle 300 Cycles Per Hour
Manufacturer Nice | HySecurity
Operating Time 3s open / 3s close
Manual Download PDF file
Specification Sheet Download PDF file